Last Modified: 11-29-2007 |
1.6 G |
|
Service Category: Engine/Hybrid System |
Section: Cooling |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000002CW400AX |
|
Title: 2UZ-FE COOLING: THERMOSTAT: INSPECTION (2008 Sequoia) |
INSPECTION
1. INSPECT THERMOSTAT
HINT:
The valve opening temperature is inscribed on the thermostat.
|
(a) Immerse the thermostat in water, and then gradually heat the water.
|
(b) Check the valve opening temperature of the thermostat.
Standard valve opening temperature:
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the thermostat.
|
(c) Check the valve lift.
Standard valve lift:
10.0 mm (0.394 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.
|
(d) Check that the valve is fully closed when the thermostat is at a low temperature (below 40°C (104°F)).
If not fully closed, replace the thermostat.
|