Last Modified: 11-29-2007 1.6 G
Service Category: Engine/Hybrid System Section: Cooling
Model Year: 2008 Model: Sequoia Doc ID: RM000002CW400AX
Title: 2UZ-FE COOLING: THERMOSTAT: INSPECTION (2008 Sequoia)

INSPECTION

1. INSPECT THERMOSTAT



HINT:

The valve opening temperature is inscribed on the thermostat.


(a) Immerse the thermostat in water, and then gradually heat the water.

(b) Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)

If the valve opening temperature is not as specified, replace the thermostat.


(c) Check the valve lift.

Standard valve lift:

10.0 mm (0.394 in.) or more at 95°C (203°F)

If the valve lift is not as specified, replace the thermostat.

(d) Check that the valve is fully closed when the thermostat is at a low temperature (below 40°C (104°F)).

If not fully closed, replace the thermostat.